Company Profile

DVLPC was founded in 2000 for the purpose of constructing, supplying & installing for protection against natural disaster that had been threatening to the earth, such as (Lightning).DVLPC is an expert company with many-year experience in installing lightning protection system with a lot of achievements, such as Telecommunication antenna,Big building, Cambodia National Assembly, The Peace house, Mechanic building, The Prime Minister's house, The President of Cambodia National Assembly's house etc.

Keywords

Alhec terra streamerIndelec Alltec terrastreamer

Our Lightning Protection System

Our Lightning Protection System was installed by high experience team of technicians that specialized in working at the height. Especially, all the works fulfilled by DVLPC have gone through accurate calculation and design in line with International Standard (NF C 17-102).
Furthermore, DVLPC has many-year experience in construction and maintenance.

Our Services:

  • Supply of Lightning Protection Products.  
  • Specializes in installing Lightning Protection System with High Quality & International Standard (NF C 17-102).       
  • Control & Maintenance.     
  • Electrical & Water System. 
  • Security Camera System.
  • Fire fighting & Fire Alarm System.

Lightning Protection System commercial/industrial installation

FIG. 2 Lightning protection system commercial/industrial installation 1) air terminals spaced 20 feet apart around the perimeter of the building) down conductors) ground rods at least 10-feet deep) art handling units bonded to system (may be in need of air terminals mounted on unit)) air terminals mounted within two feet of outside corner) mid-roof conductor and air terminals at maximum 50-foot spacing) grounded metal bodies bonded into system) surge arresters installed at main electrical panels) transient voltage surge suppressors installed in receptacles to protect computers and other office equipment.
1

Lightning Protection System for a dwelling

FIG. 1 Lightning protection system for a dwelling) air terminals spaced 20 feet apart along ridges and within two feet of ridge ends) down conductors) minimum of two groundings at least 10-feet deep) roof projections such as weather vanes connected to system) air terminal located within two feet of outside corners of chimney) dormers protected) antenna mast connected to roof conductor) connect gutters or other grounded metals as required) surge arrester installed at service panel to protect appliances) transient voltage surge suppressors installed in receptacles to which computers and other electronic equipment are connected. 2

ELLIPS Lightning Rod ESE

ELLIPS Early Streamer Emission (ESE) lightning rod is the result of over 10 years of research and laboratory experiments and field test. Combining advanced materials and technologies, ELLIPS ESE lightning rod is thought out to optimize the whole of your lightning protection system. Each ELLIPS ESE lightning rod can be test  by wired- controlled tester or remote- controlled tester ( ELLIPS Contact option ). ELLIPS aesthetics and colors allow its integration within all possible drafts and structures ( 8 colors available - not effect on operation ).
3

Liva Ative Lightning Rod Type Selection and Protection Diameter

Calculation for Protection Fields of Active Lightning Rod
The protection fields of Active Lightning Rods can be calculated
with the formula below.
In this formula;
Rp: radius of protection in a horizontal plane situated
at a vertical distance h of the rod.
h: height of the top of the point of the rod above the area to protect.
D: Lightning advancement step or leaping interval of lightning along the way.
-For this reason it is the protection level parameter.
"D'' Value;
-For level I protection D=20 m
-For level II protection D=45 m
-For level III protection D=6 m


21

INGESCO PDC Lightning Rod

Description
Lightning rod with non-electronic ESE (Early Streamer Emission) system, standardized
according norms UNE 21.186 and NFC 17.102.
Adaptable to all types of buildings.
Application standards:
  • UNE 21.186
  • NFC 17.102
  • UNE-EN 50164/1
  • UNE-EN 62.305
01

Head-Mast Adaptor Piece

Description
Necessary to connect the air terminal to the mast.
Facilitates the connection of the head to the conducting network.
Available in two models: for connection to cable or rod conductive networks and for connection to 30x2mm tape conductive networks.
Complies with the requirements set forth in the standards:

  • EN 62.305
  • EN 50.164/1

Made of Cu/Zn alloy (brass).
Stainless steel hardware. 2

Mast Anchor Set: Double Anchoring

Description
Useful for vertical fastening of masts to various structures.Permits fastening 1'½" and 2" tubes. Consult for other measurements.Set of two pieces made of hot galvanized steel.

Model
Double Anchor Clamp 1'½" - 1'½"
Double Anchor Clamp 1'½" - 1'¼"
Double Anchor Clamp 1'½" - 2"
Double Anchor Cross Clamp 1'½" - 1'½" 4

National Distribution

Electrical equipment distributors offer installers, engineering firms and consumers a wide range of products and integrated solutions to protect against lightning.The distribution covers the whole Spanish territory and a large number of countries in the export, with a high proportion of outlets and availability of stock locally.This network makes it possible to meet the needs of our customers by minimizing the delivery of our products.Our extensive catalog of products with the badges of our LABELEC Testing Laboratory, offers our customers the most complete and functional range of external protection. kj